Exosome/EV Isolation Kit
Choose the right sEV isolation column
01 Column Format
Standard-Y
Compact Column
10mL column volume
Y: High-Yield version
Standard-P
Compact Column
10mL column volume
P: High-Purity version
Maxi-Y
Large Column
30mL column volume
Y: High-Yield version
Maxi-P
Large Column
30mL column volume
P: High-Purity version
Standard Column
- 9 columns per box
- Recommended sample loading volume per column: 0.2–1.5 mL
- Ideal for limited or precious clinical samples

Internal Structure Annotation

Chromatography Column Display

Outer Packaging Annotation
Standard-Y
Kit 1
Reusable up to 5 times
9 columns
Elution Buffer (10x):
1 x 120mL
Equilibration Buffer (10x):
2 x 100mL
Kit 2
Single Use
9 columns
Elution Buffer (10x):
1 x 60mL
Equilibration Buffer (10x):
1 x 60mL
Standard-P
Kit 1
Reusable up to 5 times
9 columns
Elution Buffer (10x):
1 x 120mL
Equilibration Buffer (10x):
2 x 100mL
Kit 2
Single Use
9 columns
Elution Buffer (10x):
1 x 60mL
Equilibration Buffer (10x):
1 x 60mL

Chromatography Column Display
Maxi column
- 5 columns per box
- Recommended sample loading volume per column: 1.5–5 mL
- Suitable for higher‑volume samples and batch processing

Display of Two Chromatography Column Formats
Maxi-Y
Kit 1
Reusable up to 5 times
5 columns
Elution Buffer (10x):
1 x 120mL
Equilibration Buffer (10x):
2 x 100mL
Kit 2
Single Use
5 columns
Elution Buffer (10x):
1 x 60mL
Equilibration Buffer (10x):
1 x 60mL
Maxi-P
Kit 1
Reusable up to 5 times
5 columns
Elution Buffer (10x):
1 x 120mL
Equilibration Buffer (10x):
2 x 100mL
Kit 2
Single Use
5 columns
Elution Buffer (10x):
1 x 60mL
Equilibration Buffer (10x):
1 x 60mL
Intended Use
Exosome Extraction Kit for separation and extraction of exosomes from human serum and plasma using size‑exclusion chromatography (SEC) for clinical in vitro testing.
Storage & Shelf Life
Store at 2°C–30°C. Shelf life: 12 months. Refer to the outer package for production date, shelf life and expiry date.
Applicable Instrument
Exosome Automated Extraction Platform: ExoFaster‑500.

Exosomes are separated and extracted through agarose gel with a defined pore size based on the SEC principle, enabling gentle, high‑purity isolation of extracellular vesicles.
For use by trained laboratory professionals in clinical and research laboratories.
Serum and plasma samples can be stored at 2°C–8°C for up to 3 days, or at ≤‑70°C for up to 1 month. Avoid repeated freeze–thaw cycles. In case of obvious precipitation, centrifuge to obtain the supernatant.