One-Step, High-Purity EV Isolation with Composite Columns

Updated: 1 day ago
Introduction: the purity challenge in EV isolation
EVs carry proteins, nucleic acids and lipids that reflect their cell of origin, which makes them attractive as biomarker sources and therapeutic vehicles. Isolating them cleanly from complex biofluids is still a major challenge.
Conventional SEC preserves EV integrity and removes most soluble protein, but it cannot distinguish particles of similar size. In plasma and serum, lipoproteins (LDL, VLDL, chylomicrons) outnumber EVs by orders of magnitude and overlap them in size, so they co-elute.
For proteomics and LC-MS, these lipoprotein contaminants (ApoB, ApoA-I, ApoE and others) dominate the spectra and mask low-abundance EV proteins. Removing them usually means adding a second purification step, such as density gradient or affinity capture, which costs time and lowers recovery.
The Composite series is designed to solve this in one step.
Principle of the Composite columns
Composite columns integrate two separation mechanisms in one bed:
Size exclusion. EVs are large and are excluded from the resin pores, eluting early in the void-volume fractions. Small soluble proteins such as albumin enter the pores and elute later.
Ligand-activated core-shell capture. The resin core carries ligands that provide hydrophobic and ion-exchange interactions. Lipoproteins and other contaminants that would otherwise co-elute with EVs are bound and retained, while EVs pass through.
The result is an EV fraction that is depleted of both soluble proteins and lipoproteins, collected in the same simple gravity or automated workflow as standard SEC, with no extra steps.

Materials and methods
Columns and instrument
Composite series columns, Standard format or Maxi format
For comparison: Y series and P series SEC columns in the same formats
Samples
Human Plasma
Results
Lipoprotein and protein depletion across column series
Removal Rate (%) | Y series | P series | Composite series | ||||||
Fraction | ApoA-I | ApoB | HSA | ApoA-I | ApoB | HSA | ApoA-I | ApoB | HSA |
6 | >99% | 100.000% | 99.999% | >99% | 100.000% | 99.998% | >99% | >99% | 99.999% |
7 | >99% | 96.923% | 99.990% | >99% | 93.846% | 99.989% | >99% | >99% | 99.996% |
8 | >99% | 80.000% | 99.967% | >99% | 87.692% | 99.982% | >99% | >99% | 99.983% |
9 | >99% | 80.000% | 99.960% | >99% | 87.692% | 99.982% | >99% | >99% | 99.935% |
All three series remove essentially all albumin and HDL. The difference lies in LDL: because LDL overlaps EVs in size, pure SEC can only partly remove it. The Composite series adds ligand-based capture and depletes >99% of LDL (ApoB), the main contaminant that limits plasma and serum EV proteomics.

Purity: Composite achieved the highest particle-to-protein ratio (721 ×10⁶ particles/µg), 3.0-fold higher than Y series and 2.4-fold higher than P series.
Protein removal: Composite eluate contained only 0.143 mg/mL protein, 69% lower than Y series and 45% lower than P series.
Particle recovery (NTA): Composite yield (103 ×10⁹/mL) was comparable to Y series (92%) and 32% higher than P series.
Overall, the Composite column improves purity mainly by removing more host-cell protein, without sacrificing particle recovery, outperforming both Y and P series controls.
Choosing the right column

Composite series | P series | Y series | |
Focus | Maximum purity | Balanced recovery and purity | Maximum recovery |
Separation | SEC + hydrophobic + ion-exchange | SEC | SEC |
Yield | 10^9 - 10^11 particles/mL | 10^9 - 10^11 particles/mL | 10^10 - 10^12 particles/mL |
Best for | Complex, protein-rich samples (plasma, serum) | Routine EV isolation | Low-EV or precious samples |
Typical downstream use | Proteomics, LC-MS | Protein and RNA analysis | General EV characterisation |
Use the Composite series when lipoprotein carry-over would compromise your results, particularly for plasma or serum proteomics and LC-MS-based biomarker discovery.
Conclusion
The Composite series brings two separation mechanisms into one column, a combination rarely found in commercial EV isolation products. It keeps the speed, gentleness and simplicity of SEC while adding the selectivity needed to remove lipoproteins. With >99% LDL (ApoB) depletion in a single step, it gives researchers working with plasma, serum and other complex samples a cleaner starting material for proteomics and LC-MS, without a second purification step.

